Days to Ship |
|
---|
Venn
[Features]
· General-purpose drain trap for pipelines and headers etc. Each of the mechanisms are attached to the cover for easy maintenance.
· A simple internal valve structure for easy maintenance.
· Features a built-in strainer.
· However, for the Ministry of Land, Infrastructure, Transport and Tourism specification, install an 80-mesh strainer to the trap inlet.
Configure Now
Ships as soon as | 4 Days |
---|
Venn
Small capacity (MAX 2.0MPa) bucket type steam trap. Can be used for laundry machines, heating equipment, in the food industry, and for medical equipment.
[Features]
· Utilizes SSR-Shockless Self Return- mechanism.
· Reduced shock when the valve is closed. The valve self-closes independently of the buoyancy of the bucket, allowing it to be used with low pressures to high pressures.
· Features a compact body for easy installation in confined places.
· Features a built-in strainer. However, with the Ministry of Land, Infrastructure, Transport and Tourism specification, install an 80-mesh strainer to the trap primary side.
Configure Now
Ships as soon as | 7 Days |
---|
Yoshitake
The stainless steel disc and valve have been specially heat-treated for superior durability. A built-in strainer type.
Configure Now
Ships as soon as | 4 Days |
---|
BELL-MIGHTY Steam Trap, ES5/E5/8N/8B/10/12N Type
Miyawaki
• Compatible Fluid: Steam
• Type: Steam trap
• Drain Trap/Steam Trap Method: Bucket Type
Configure Now
Ships as soon as | 17 Days |
---|
Hokuto
An energy saving and cost effective type. Reduced steam consumption and increased pump discharge. Boasts an expanded operating range for use with different applications. Suction height: MAX6m, discharge height: MAX20m. Technical data can be INPUT to PC.
Configure Now
Ships as soon as | 4 Days |
---|
Star Water Jet Eductor, PS Type
Hokuto
An energy saving and cost effective type. Boasts an expanded operating range for use with different applications. Suction height: MAX6m, discharge height: MAX20m. Technical data can be INPUT to PC.
Configure Now
Ships as soon as | 4 Days |
---|
Yoshitake
[Features]
· Features four functions: STOP/BY-PASS/TRAP/TEST. These functions can be easily switched between using a spanner or an adjustable wrench etc.
· Features a built-in bypass function which significantly reduces piping and construction costs.
· The adoption of welded bellows allows use with a broad range of pressures.
· Operates at a temperature 12°C below saturation temperature. No discharge of live steam.
· Unaffected by back pressure. Allows for the trap to be checked.
· The cock and valve seat are integrated as one and made of stainless steel.
· A built-in strainer type.
· Optional horizontal/vertical installation. (Lift the cover for mounting vertically, horizontally, and everything in between.)
Configure Now
Ships as soon as | 4 Days |
---|
Combined Disc Type Steam Trap and Bypass Valve, SV1 Type
Miyawaki
• Compatible Fluid: Steam
• Type: Steam trap
• Drain Trap/Steam Trap Method: Disc Type
• Connection: Rc
• Max. Operating Pressure (mpa): 1.6
Configure Now
Ships as soon as | 5 Days |
---|
BELL-MIGHTY Steam Trap, ER105/110/116/120/25 Type
Miyawaki
• Compatible Fluid: Steam
• Type: Steam trap
• Drain Trap/Steam Trap Method: Bucket Type
Configure Now
Ships as soon as | 17 Days |
---|
Disc Type Steam Trap, SU2N/SU2H Type
Miyawaki
• Compatible Fluid: Steam
• Type: Steam trap
• Drain Trap/Steam Trap Method: Disc Type
• Max. Operating Pressure (mpa): 4.6
• Body Material: Stainless Steel (SUS420J2)
Configure Now
Ships as soon as | 17 Days |
---|
Drainage Separator, DS-1/2 Series
Yoshitake
The drainage is efficiently separated using the centrifugal force generated by the channeling of steam and air.
Configure Now
Ships as soon as | 4 Days |
---|
Yoshitake
[Features]
· The valve and seat are made using stainless steel for excellent durability (TF-2 type).
· Features a built-in air venting valve which significantly reduces the risk of air obstruction.
· A float and lever-type trap with reliable operation and a large discharge capacity.
Configure Now
Ships as soon as | 7 Days |
---|
Steam Traps, TD-10NA/30NA Series
Yoshitake
The use of bimetal eliminates air obstructions. Cold water and air are simultaneously discharged during start-up, providing an efficient start-up for steam equipment.
Configure Now
Ships as soon as | 4 Days |
---|
ATB-5 Type Steam Trap with Bypass (Triple Function)
Venn
An integrated compact structure incorporating three functions. In addition to functioning as a thermostatic type trap, it can also be used as a bypass circuit, and a stop valve.
Effective for better utilization of space and for reducing equipment costs.
[Features]
· Boasts a large discharge capacity and so can be used for everything from pipe ends to large-type equipment.
· Operates at a temperature 10°C below saturation temperature, helping save on energy by ensuring no discharge of live steam and no valve body blanking.
Note: Types with nominal diameters of 32 to 50 operate at a temperature 15°C lower.
· For types with a nominal diameter of 32 to 50, the adoption of a movable valve body provides excellent sealing performance and durability.
· The test valve can be directly mounted to the trap.
Configure Now
Ships as soon as | 4 Days |
---|
A3N/AF3N, Disk / Steam Trap / Up - 1.6 MPaG, A3N
TLV
• Compatible Fluid: Steam
• Type: Steam trap
• Drain Trap/Steam Trap Method: Disc Type
• Connection: R(Rc)
• Max. Operating Pressure (mpa): 1.6
Configure Now
Ships as soon as | 4 Days |
---|
Combined Disc Type Steam Trap and Bypass Valve, SV-N Type
Miyawaki
• Compatible Fluid: Steam
• Type: Steam trap
• Drain Trap/Steam Trap Method: Disc Type
• Max. Operating Pressure (mpa): 1.6
• Body Material: FC250
Configure Now
Ships as soon as | 4 Days |
---|
Miniature Disc Type Steam Trap, SD1 Type
Miyawaki
• Compatible Fluid: Steam
• Type: Steam trap
• Drain Trap/Steam Trap Method: Disc Type
• Connection: Rc
• Max. Operating Pressure (mpa): 2
Configure Now
Ships as soon as | 4 Days |
---|
Brand |
---|
Product Series |
CAD |
Days to Ship |
Types |
Drain/Steam Trap Method |
Compatible Fluid |
Connection |
Nominal Diameter |
Maximum Operating Pressure(MPa) |
Body Material |
Brand | Venn | Venn | Yoshitake | Miyawaki | Hokuto | Hokuto | Yoshitake | Miyawaki | Miyawaki | Miyawaki | Yoshitake | Yoshitake | Yoshitake | Venn | TLV | Miyawaki | Miyawaki |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Product Series | |||||||||||||||||
CAD |
|
|
|
|
| ||||||||||||
Days to Ship | 4 Days | 7 Days | 4 Days | 17 Days | 4 Days | 4 Days | 4 Days | 5 Days | 17 Days | 17 Days | 4 Days | 7 Days | 4 Days | 4 Days | 4 Days | 4 Days | 4 Days |
Types | Steam trap | Steam trap | Steam trap | Steam trap | Related Components | Related Components | Steam trap | Steam trap | Steam trap | Steam trap | Drain Separator | Steam trap | Steam trap | Steam trap | Steam trap | Steam trap | Steam trap |
Drain/Steam Trap Method | Bucket Type | Bucket Type | Disc Type | Bucket Type | - | - | Bellow type | Disc Type | Bucket Type | Disc Type | - | Float type | Disc Type | Thermowax Expressions | Disc Type | Disc Type | Disc Type |
Compatible Fluid | Steam | Steam | Steam | Steam | Steam | Fluid | Steam | Steam | Steam | Steam | Steam / Gas | Steam | Steam | Steam | Steam | Steam | Steam |
Connection | R(Rc) | R(Rc) | - | Flange ~ R(Rc) | R(Rc) | R(Rc) | - | R(Rc) | Flange ~ R(Rc) | Flange ~ Socket weld | Flange ~ R(Rc) | - | Flange ~ R(Rc) | R(Rc) | R(Rc) | Flange ~ R(Rc) | R(Rc) |
Nominal Diameter | 15A ~ 25A | 15A ~ 25A | 15A ~ 25A | 15A ~ 50A | - | - | 15A ~ 25A | 10A ~ 25A | 15A ~ 50A | 15A ~ 25A | 15A ~ 100A | 15A ~ 80A | 15A ~ 25A | 15A ~ 25A | 15A ~ 25A | 15A ~ 25A | 8A ~ 15A |
Maximum Operating Pressure(MPa) | 0.7 ~ 1 | 0.3 ~ 2 | 4.2 | 1.6 ~ 2.1 | - | - | 1 | 1.6 | - | 4.6 | 2 | 0.3 ~ 0.7 | 1 ~ 2 | 1 | 1.6 | 1.6 | 2 |
Body Material | Cast Iron | Cast Iron | - | Stainless Steel ~ Steel | Copper ~ Stainless Steel | Copper | - | Steel | Steel | Stainless Steel | Cast Iron | - | Cast Iron | Cast Iron | Cast Iron | Steel | Stainless Steel |
Loading...
How can we improve?
How can we improve?
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Customer Privacy Policy
Thank you for your cooperation.
While we are not able to respond directly to comments submitted in this form, the information will be reviewed for future improvement.
Please use the inquiry form.
Customer Privacy Policy